Check Valve (Non Chatter) 2702-100

check valve
Non Chatter Check Valve 2702-100

Originally designed and built for a major aerospace firm to replace a valve that was prematurely failing due to chatter. Chatter causes premature wear and a valve can be ruined in a few hours.

Hydracon designed this check valve to provide a long service life and to survive 3,000 reverse water hammer pressure cycles. This design incorporates features justified by countless savings in replacement, maintenance and downtime costs.

Drawing 2702-100

Specifications:

  1. Bubble-tight closure
  2. Contamination tolerant seat
  3. System operating pressure: 3,000 psi
  4. Full flow.  ESEOD: 0.14” (Cd: 0.38)
  5. System fluid: liquid or gas
  6. Ports: 1/4” male tube
  7. Size:  .75” hex x 1.8” long
  8. Weight:  < 2 oz.
  9. Stainless steel wetted surfaces

Also available - Check Valve 2702-300 - 1" Full Flow; Check Valve 2706-100 - 2" Full Flow